Product
Everything ProcessView+ does
One platform to run your chambers, log every reading, and generate the proof — built for today's compliance and IT requirements. No programming, no integrators.
ProcessView+ is also a direct replacement for Watlow's legacy WatView® software, discontinued around the Windows 7 release, on the same controllers.
Profile editing & control
Create and edit temperature and humidity profiles, then run them across your network from one screen.
- Download, read, start, stop, pause, and resume profiles
- Control one chamber or all 25 at once
- No scripting — point, click, run
Batch information & traceability
Define the fields your process actually needs — more than fifty of them, named by you — and every run carries them from the operator's screen through to your enterprise database.
- Five groups and fifty-two fields you name yourself, each switched on or off and optionally made mandatory — plus four fixed identity fields the log file name is built from
- Turn on required fields and a run will not start until they are filled — and the last run's values are cleared first, so nothing carries over by accident
- Map product numbers to profiles: type or scan a product ID and the matching recipe is selected and locked
- Every value follows the run — into the log file name, the session record, the QA report, the CSV backup, your SQL Server, and a retained MQTT message
Data logging
Every reading is logged to a local database on your own machine and mirrored to your SQL Server.
- Configurable logging intervals
- Tamper-evident data files — an altered backup is detectable
- Real-time SQL Server mirroring — no exports
Historical data viewer
Every session you have ever logged, searchable — then charted, analysed, exported or overlaid against another run without leaving the window.
- Filter by profile, equipment or date range — or search across every batch field, so one work-order number finds every run that carried it
- Analytics per zone: minimum, maximum and average, deviation from setpoint, overshoot and undershoot with the time each occurred, and heating and cooling ramp rates in °/min
- Per-step breakdown beside the batch inputs the run was logged under
- Overlay runs to compare, export to CSV or PDF, or check an exported backup against its integrity chain
QA reports & tolerance bands
Every finished run is judged against its own per-step tolerance bands and becomes an audit-ready PDF. The verdict has three states, because "did this run pass" is not always a yes or a no.
- PASS, REVIEW or FAIL — a critical zone that only touched its warning band is flagged for a person, not quietly passed
- Warn and alarm bands per step, each step set critical, advisory or monitor-only
- Excursion table — zone, step, tier, peak deviation, entered and exited
- Per-step statistics, plus run-vs-history comparison to catch drift
Thermal qualification — TUS, SAT & calibration
Run AMS 2750 uniformity surveys and system accuracy tests from the same software that runs the chamber, and certify them with the same signature workflow.
- Temperature uniformity surveys — hot and cold spot, spread and maximum deviation against class tolerance
- System accuracy tests with configurable tolerances and sign-off
- Calibration wizard and calibrator records, with correction factors applied and shown
- Certification PDFs carrying operator and reviewer sign-off
Alarms & alerts
Know the moment something needs attention — at the bench or on your phone.
- Configurable software alarms
- Email and SMS notifications
- Alerts on run completion or alarm trigger
Web server & dashboards
A built-in web server puts live chamber data on any browser or phone, anywhere.
- Web and mobile dashboards
- View status from any device
- MQTT v5 over TLS to a broker you run — self-host on AWS or Azure
Remote PC client
Monitor your chambers from a second PC over MQTT, away from the main station.
- Connects to your ProcessView+ server
- Live monitoring from a remote PC
- Sold separately — see pricing
Simulation Mode (Virtual F4T)
Run the entire product against a built-in virtual Watlow F4T — no controller, no network, no risk.
- Try everything with zero hardware or setup
- Two live control loops — temperature and humidity — responding to your setpoints
- Rehearse SAT, TUS, and Part 11 signing without touching real records
The verdict
A run that needs a second look isn't a failure
Most chamber software prints a stamp: pass, or fail. But a critical zone that brushed its warning band for nine seconds is neither. Call it a pass and the excursion disappears into the archive. Call it a failure and you have scrapped good product and opened an investigation you did not need.
ProcessView+ has a third verdict. Every step carries a warn band and an alarm band, and you decide what each step is worth — so the software escalates the way your quality procedure already does.
The point is what it does to the other two. FAIL means something: it is reserved for a critical step breaching its alarm band. When a run fails, nobody has to relitigate whether it really did — and the excursion table names the zone, the step, the peak deviation and the window, so the argument is about the process, not the paperwork.
And the times in that table are the times on the run's own trend chart. A reviewer can go and find the excursion rather than taking the table's word for it — the two halves of the document agree, which is the first thing anyone checks and the thing most reports quietly get wrong.
| Step is set | Warn band breached | Alarm band breached |
|---|---|---|
| Monitor only | Recorded | Recorded |
| Advisory | Recorded | Review |
| Critical | Review | Fail |
A monitor-only step is recorded and charted, but never changes the verdict — the one setting guaranteed to be inert.
Screenshots
See it in action
Click a screenshot to enlarge.
Ready to see ProcessView+ on your chambers?